Change Language
EI-133 Fine Particulate Sampler

EI-133 Fine Particulate Sampler

52000 INR/Unit

Product Details:

  • Display Type Digital display
  • Air Flow 1.0 to 1.5 m/min (adjustable)
  • Orientation Floor-standing
  • Efficiency High-efficiency particle collection (PM2.5 and PM10)
  • Sensor Type Gravimetric filter paper
  • Instruments Type Fine particulate sampler
  • Usage & Applications Ambient air quality monitoring
  • Click to View more
X

EI-133 Fine Particulate Sampler Price And Quantity

  • 52000 INR/Unit
  • 1 Unit

EI-133 Fine Particulate Sampler Product Specifications

  • Designed for 24-hour sample collection
  • Ambient, suitable for Indian climate
  • Fine particulate sampler
  • Ambient air quality monitoring
  • High-efficiency cooling fan system
  • Continuous operation
  • Semi-Automatic
  • 220-440 Volt (v)
  • 1.0 to 1.5 m/min (adjustable)
  • Digital display
  • High-efficiency particle collection (PM2.5 and PM10)
  • Floor-standing
  • EI-133 Fine Particulate Sampler
  • Gravimetric filter paper
  • PM2.5/PM10 concentration
  • Below 65 dB
  • As per available Millimeter (mm)
  • As per available Kilograms (kg)
  • Coated metal for weather resistance
  • Electric
  • Metal

EI-133 Fine Particulate Sampler Trade Information

  • Cash in Advance (CID)
  • 50 Unit Per Month
  • 20-25 Days
  • All India

Product Description

EI-133 Fine Particulate Sampler is a specific type of air sampling device designed to collect fine particles, often referred to as PM2.5 (particulate matter with an aerodynamic diameter less than 2.5 micrometers). The flow rate of the sampler is critical for accurate measurements. The flow rate of the sampler is critical for accurate measurements. It is often set to ensure a specific volume of air is sampled over a defined period. It is often set to ensure a specific volume of air is sampled over a defined period. EI-133 Fine Particulate Sampler plays a crucial role in monitoring air quality in urban areas, industrial sites, and other locations where fine particles can pose health risks.



Advanced Simultaneous PM2.5 & PM10 Sampling

Efficiently collect air particulate samples for both PM2.5 and PM10 using dual sampling channels, streamlining ambient air quality analysis. The EI-133s gravimetric technology and robust filter holder ensure accurate results, ideal for environmental monitoring in urban and industrial regions.


Automatic Flow Control & Programmable Operation

The sampler boasts automatic, constant flow control and a fully programmable timer, allowing up to 24-hour continuous sampling. This ensures consistent sample quality and reliability, reducing manual intervention and making it suitable for extended field deployments.


User-Friendly Portability and Digital Connectivity

Designed with a portable wheel assembly and compact, coated metal cabinet, the EI-133 is easy to transport and set up on-site. With digital display and USB/RS232 data output, transferring and managing sampling information is both convenient and efficient for users in various monitoring scenarios.

FAQs of EI-133 Fine Particulate Sampler:


Q: How does the EI-133 Fine Particulate Sampler operate for air quality monitoring?

A: The EI-133 uses gravimetric sampling technology with standardized 47 mm filter paper to collect particulate matter (PM2.5 and PM10). It draws ambient air through the filters using a high-flow rotary vane vacuum pump, with automatic constant flow control ensuring consistent sample collection for up to 24 hours.

Q: What accessories and calibration tools are included with the EI-133 sampler?

A: The sampler comes complete with filter papers and a flow calibration kit, enabling immediate setup and accurate performance verification. These tools facilitate both initial installation and routine maintenance, enhancing operational reliability.

Q: Where can the EI-133 sampler be used and what are its key applications?

A: This sampler is designed for ambient air quality monitoring in environments such as urban areas, industrial sites, and research stations. Its weather-resistant, powder-coated metal surface and broad operating temperature range make it particularly suitable for the varied Indian climate.

Q: What benefits does the automatic flow control offer to users?

A: Automatic constant flow control maintains sample integrity by ensuring a steady air flow rate (1.0 to 1.5 m/min), regardless of filter loading or environmental conditions. This results in more accurate and reproducible particle concentration measurements.

Q: How can users retrieve and manage sampling data from the EI-133?

A: Data can be transferred directly via USB or RS232 interfaces to external computers or storage devices. The clear digital display also allows real-time monitoring of sampling status and parameter settings, simplifying data handling and analysis.

Q: When should the filter paper be replaced during sampling operations?

A: The filter paper should ideally be replaced after each 24-hour sampling session, or sooner if high particulate loadings are expected. Regular replacement ensures accurate gravimetric readings and maintains the efficiency of particle collection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Air Pollution Monitoring Equipment' category



Back to top